Some Firefox users may need to log in more than once to log in. It's a known Firefox bug. Check "keep me logged in," it might help.

Es posible que algunxs usuarixs de Firefox tengan que conectarse más de una vez para iniciar sesión. Es un error conocido de Firefox. Marca "keep me logged in" (mantenerme conectado), puede ayudar.


Keyless Entry: Difference between revisions

From Bike Collectives Wiki
 
(4 intermediate revisions by the same user not shown)
Line 44: Line 44:
* Since we are using the PowerDSine, we don't need to use the external power supply to the PCON.
* Since we are using the PowerDSine, we don't need to use the external power supply to the PCON.
* The system is 12v, so the HES 5000 Series Strike does '''not''' need to be rewired ([http://www.hesinnovations.com/hes2/Templates/5000--InstallRevG.pdf page 5]).
* The system is 12v, so the HES 5000 Series Strike does '''not''' need to be rewired ([http://www.hesinnovations.com/hes2/Templates/5000--InstallRevG.pdf page 5]).
== Software ==
=== Definitions ===
'''Locked''': Only registered smart card holders can enter the building, but anyone can exit the building by pulling the paddle handle.
'''Unlocked''': Anyone one can enter and exit the building.
=== Goal ===
At the [[Salt Lake City Bicycle Collective]] our shop has Open Shop Nights on Monday, Tuesday and Thursday from 5-9pm.  So we wanted to schedule the door to be unlocked from 5-9pm on those days and remain locked the rest of the time.  However, in the event a volunteer was late, we didn't want the door to unlock itself with no one we knew around, so ideally it would stay locked until a volunteer is in first and then automatically lock it down again when the shop closes at 9pm.
=== Intelli-M Supervisor Plus or Web Interface ===
The Intelli-M can be accessed using an Internet Browser (Firefox, Internet Explorer, etc.,...) or by using an PC application called Intelli-M Supervisor Plus.  At present time these two methods don't work together, so you have to pick one.  As we found out the PC application has more features.
Generally speaking, our ideal access policy was accomplished using the '''Intelli-M Supervisor Plus''' (not the web interface) by applying a '''Schedule''' to the '''Access Service Programming''' where volunteers are listed under the '''First In''' tab.

Latest revision as of 22:57, 5 January 2008

Keyless entry is when someone doesn't need a traditional key to open a door, instead the key is replaced with a number pad and/or electronic sensor and some kind of RFID tag.

The "Key" Problem

At the Salt Lake City Bicycle Collective we had a proliferation of keys to our shop, mostly legitimate, some not. This was mainly the result of not having a solidified volunteer structure and a laxed key policy for who had access to the shop. The issue was that every time a volunteer would copy, lose, move, or go MIA -- there would be an unaccounted master key to our shop floating around.

Possible Solutions

Re-key the Door

To re-key the door and provide copies to all the legitimate people on the key list would cost around $100 and $3 per key. We could do this, but then we didn't want to do it again.

Re-key the Door with a Special Key

Most Locksmith shops have a proprietary system that in theory only they can make copies of. They keep a list of authorized people from your organization, so when someone comes to make a copy, they have to present photo ID before they get a copy. This was around $200 and $7 per key. However we still would have to deal with the lost key problem.

Number Pad Keyless Entry

We considered using a number pad, but in today's world of fast cell phone texting that didn't seem like a good idea at all.

Smart Key (RFID) Entry

This uses a card reader that smart cards (passive RFID) that look like thick credit cards and/or keychains are waved by. The downside is that it is by far the most technical, expensive and complex of all the solutions. On average outfitting a single door was around $2,500 -- luckily we were able to get almost everything donated.

  1. A log is kept which holds people accountable for using the shop off hours.
  2. RFID cards are granted and denied access, so if someone loses a card -- we just disable that card.
  3. We have the ability to grant limited access -- so someone can only open the door for an hour on a given day.
  4. Web based control.

Howto Install Keyless Entry

Parts

Installation Tips

  • Since we are using the PowerDSine, we don't need to use the external power supply to the PCON.
  • The system is 12v, so the HES 5000 Series Strike does not need to be rewired (page 5).

Software

Definitions

Locked: Only registered smart card holders can enter the building, but anyone can exit the building by pulling the paddle handle.

Unlocked: Anyone one can enter and exit the building.

Goal

At the Salt Lake City Bicycle Collective our shop has Open Shop Nights on Monday, Tuesday and Thursday from 5-9pm. So we wanted to schedule the door to be unlocked from 5-9pm on those days and remain locked the rest of the time. However, in the event a volunteer was late, we didn't want the door to unlock itself with no one we knew around, so ideally it would stay locked until a volunteer is in first and then automatically lock it down again when the shop closes at 9pm.

Intelli-M Supervisor Plus or Web Interface

The Intelli-M can be accessed using an Internet Browser (Firefox, Internet Explorer, etc.,...) or by using an PC application called Intelli-M Supervisor Plus. At present time these two methods don't work together, so you have to pick one. As we found out the PC application has more features.

Generally speaking, our ideal access policy was accomplished using the Intelli-M Supervisor Plus (not the web interface) by applying a Schedule to the Access Service Programming where volunteers are listed under the First In tab.